The zone class shows how often an explosive atmosphere is present. In Zone 1 (gas) and Zone 21 (dust) it is likely in normal operation, so devices need equipment protection level Gb / Db, for example a marking of Ex ib IIC T4 Gb. In Zone 2 and Zone 22 it is unlikely and short-lived, so level Gc / Dc is enough, for example Ex ic IIC T4 Gc. A Zone 1/21 device may also be used in Zone 2/22, but not the other way round.
What the zones mean
Hazardous areas are classified by how frequently and for how long an explosive atmosphere is present. For gases, vapours and mists these are Zones 0, 1 and 2 (IEC 60079-10-1); for combustible dust, Zones 20, 21 and 22 (IEC 60079-10-2). "Zone 1/21" means the device is approved for both gas Zone 1 and dust Zone 21.
| Zone | Atmosphere | Explosive atmosphere is present | Equipment protection level (EPL) | ATEX category | Typical locations |
|---|---|---|---|---|---|
| 0 | gas, vapour | continuously, for long periods or frequently | Ga | 1G | inside tanks and vessels |
| 1 | gas, vapour | likely in normal operation | Gb | 2G | near vents, pump seals and loading racks |
| 2 | gas, vapour | unlikely, and only briefly if it occurs | Gc | 3G | areas surrounding Zone 1, open process areas |
| 20 | dust | continuously, for long periods or frequently | Da | 1D | inside silos, hoppers and dust ducts |
| 21 | dust | likely in normal operation | Db | 2D | filling, transfer and bagging points |
| 22 | dust | unlikely, and only briefly if it occurs | Dc | 3D | rooms where dust may escape after a fault |
The zone class of each area is set by the site design and its hazardous area classification, not by the equipment supplier. The examples above are typical and do not replace project documentation.
How to read an Ex marking
The marking on the label shows which atmosphere and zone a device is approved for. Take Ex ib IIC T4 Gb, the marking of the i.safe MOBILE IS540.1 smartphone:
| Element | Meaning |
|---|---|
| Ex | explosion-protected equipment to the IEC 60079 series |
| ib | intrinsic safety, level ib: the circuit cannot ignite the atmosphere in normal operation or with one fault |
| IIC | gas group. IIC is the strictest (hydrogen, acetylene) and also covers IIB (ethylene) and IIA (propane) |
| T4 | temperature class: the surface does not exceed 135 °C |
| Gb | equipment protection level: high, for gas Zones 1 and 2 |
The same device carries a separate dust marking: Ex ib IIIC T135°C Db, where IIIC is the dust group (including conductive dust) and Db is the level for Zones 21 and 22.
Levels of intrinsic safety
| Level | The circuit stays safe | Zones |
|---|---|---|
| ia | with two independent faults | 0, 1, 2 |
| ib | with one fault | 1, 2 |
| ic | in normal operation | 2 |
Temperature classes: T1 up to 450 °C, T2 300 °C, T3 200 °C, T4 135 °C, T5 100 °C, T6 85 °C. A T4 device suits atmospheres that require any class from T1 to T4.
Zone 1/21 or Zone 2/22: which to choose
| i.safe MOBILE series | Marking (example) | Where it may be used |
|---|---|---|
| Zone 1/21 (models ending in .1) | Ex ib IIC T4 Gb · Ex ib IIIC T135°C Db | Zones 1, 2, 21 and 22 |
| Zone 2/22 (ending in .2) | Ex ic IIC T4 Gc · Ex ic IIIC T135°C Dc | Zones 2 and 22 only |
| Mining (ending in .M1) | I M1 Ex ia I Ma | mines with firedamp and coal dust, plus Zones 1/21 and 2/22 |
- Staff enter both Zone 1 and Zone 2: choose Zone 1/21 devices, one device covers both.
- Work in Zone 2/22 only: the Zone 2/22 series is sufficient.
- Underground workings with a methane or coal dust hazard: Group I equipment, category M1.
- A site with no hazardous areas: no Ex protection needed, RugGear rugged devices will do.
Accessories are part of the protection concept: headsets, speaker microphones, cases and batteries must be approved by the manufacturer for the specific model. Devices are charged outside the hazardous area only.
Requirements in Kazakhstan: TR CU 012/2011
Kazakhstan, like the whole Eurasian Economic Union, applies the technical regulation TR CU 012/2011 "On safety of equipment for use in explosive atmospheres". It requires mandatory certification of explosion-protected equipment and marking with the EAC mark and the Ex symbol. ATEX (European Union) and IECEx (international scheme) certificates confirm the design and serve as the basis for certification, but do not replace a TR CU certificate.
In practice: besides the ATEX / IECEx marking, ask the supplier for a valid TR CU 012/2011 certificate of conformity for the specific model. Check the current status of models in the i.safe MOBILE catalogue with our engineers.
Questions and answers
Can I use an ordinary or rugged (IP68) smartphone in a hazardous area?
No. IP68 and MIL-STD-810H describe protection against dust, water and shock, not explosion protection. Only equipment with an Ex marking for the relevant zone is allowed in a hazardous area.
Can a Zone 1/21 device be used in Zone 2/22?
Yes. Equipment with a higher protection level (Gb / Db) may be used in the less hazardous Zones 2 and 22. The reverse is not allowed: a Zone 2/22 device must not be taken into Zone 1 or 21.
Are i.safe MOBILE smartphones suitable for Zone 0?
No. Zone 1/21 smartphones, tablets and radios have level Gb (Ex ib) and are intended for Zones 1 and 2. Zone 0 requires level Ga (Ex ia), which SENSAiO wireless sensors, for example, provide.
What is the difference between ATEX and IECEx?
ATEX is EU Directive 2014/34/EU, mandatory for equipment placed on the EU market. IECEx is an international certification scheme based on the IEC 60079 standards. Their technical requirements and markings are very close. In Kazakhstan and other EAEU countries, TR CU 012/2011 is mandatory.
What does M1 mean?
Group I equipment for mines with a firedamp (methane) and coal dust hazard. Category M1 (level Ma) means the device remains safe even when an explosive atmosphere is present. Example marking: I M1 Ex ia I Ma.
Sources
- IEC 60079-10-1, Explosive atmospheres: Classification of areas, explosive gas atmospheres
- IEC 60079-10-2, Explosive atmospheres: Classification of areas, explosive dust atmospheres
- IEC 60079-0 (general requirements) and IEC 60079-11 (intrinsic safety "i")
- TR CU 012/2011 "On safety of equipment for use in explosive atmospheres"
- Directive 2014/34/EU (ATEX)
- Device markings: i.safe MOBILE manufacturer data